科技报告详细信息
Power Systems Development Facility Gasification Test Run TC11
Services, Southern Company
Southern Company Services Incorporated
关键词: Particulates;    24 Power Transmission And Distribution;    Start-Up;    Gasification;    Progress Report;   
DOI  :  10.2172/927609
RP-ID  :  None
RP-ID  :  FC21-90MC25140
RP-ID  :  927609
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

This report discusses Test Campaign TC11 of the Kellogg Brown & Root, Inc. (KBR) Transport Gasifier train with a Siemens Westinghouse Power Corporation (Siemens Westinghouse) particle filter system at the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama. The Transport Gasifier is an advanced circulating fluidized-bed gasifier designed to operate as either a combustor or a gasifier in air- or oxygen-blown mode of operation using a particulate control device (PCD). Test run TC11 began on April 7, 2003, with startup of the main air compressor and the lighting of the gasifier start-up burner. The Transport Gasifier operated until April 18, 2003, when a gasifier upset forced the termination of the test run. Over the course of the entire test run, gasifier temperatures varied between 1,650 and 1,800 F at pressures from 160 to 200 psig during air-blown operations and around 135 psig during enriched-air operations. Due to a restriction in the oxygen-fed lower mixing zone (LMZ), the majority of the test run featured air-blown operations.

【 预 览 】
附件列表
Files Size Format View
927609.pdf 4421KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:16次