科技报告详细信息
| Development of Low Maintenance, Field Ruggedized SO3 CEM | |
| Williamson, Ashley D. ; McCain, Joseph D. | |
| Southern Research Institute | |
| 关键词: Air Pollution Monitors; Samplers; Maintenance; Sulfuric Acid; 54 Environmental Sciences; | |
| DOI : 10.2172/903469 RP-ID : None RP-ID : FC26-02NT41593 RP-ID : 903469 |
|
| 美国|英语 | |
| 来源: UNT Digital Library | |
PDF
|
|
【 摘 要 】
A prototype semi-continuous monitor and associated particulate-free sample extraction probe have been developed for measuring the concentrations of SO{sub 3} and H{sub 2}SO{sub 4} in industrial flue gases. The monitor provides two measurements per hour for concentrations above 1 ppmv. The probe provides the capability of continuous operation while avoiding passing the sample through a layer of particulate and can be used as a probe for conventional controlled condensation measurements of SO{sub 3} and H{sub 2}SO{sub 4} emissions.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 903469.pdf | 2070KB |
PDF