HOM/LOM Coupler Study for the ILC Crab Cavity | |
Xiao, L. ; Li, Z. ; Ko, K. ; /SLAC | |
Stanford Linear Accelerator Center | |
关键词: Linear Colliders; Cavity Resonators; 43 Particle Accelerators; Computerized Simulation; Sensitivity; | |
DOI : 10.2172/902484 RP-ID : SLAC-PUB-12409 RP-ID : AC02-76SF00515 RP-ID : 902484 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
The FNAL 9-cell 3.9GHz deflecting mode cavity designed for the CKM experiment was chosen as the baseline design for the ILC BDS crab cavity. The full 9-cell CKM cavity including the coupler end-groups was simulated using the parallel eigensolver Omega3P and scattering parameter solver S3P. It was found that both the notch filters for the HOM/LOM couplers are very sensitive to the notch gap, which is about 1.6MHz/micron and is more than 10 times more sensitive than the TTF cavity. It was also found in the simulation that the unwanted vertical {pi}-mode (SOM) is strongly coupled to the horizontal 7{pi}/9 mode which causes x-y coupling and reduces the effectiveness of the SOM damping. To meet the ILC requirements, the HOM/LOM couplers are redesigned to address these issues. With the new designs, the damping of the HOM/LOM modes is improved. The sensitivity of the notch filter for the HOM coupler is reduced by one order of magnitude. The notch filter for the LOM coupler is eliminated in the new design which significantly simplifies the geometry. In this paper, we will present the simulation results of the original CKM cavity and the progresses on the HOM/LOM coupler re-design and optimization.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
902484.pdf | 178KB | download |