科技报告详细信息
Energy Calibration of the BaBar EMC Using the Pi0 Invariant Mass Method | |
Tanner, David J. ; U., /Manchester | |
Stanford Linear Accelerator Center | |
关键词: Calibration; Photons; Calorimeters; Statistics Instrumentation,Inst; Instrumentation,Inst; | |
DOI : 10.2172/901853 RP-ID : SLAC-R-850 RP-ID : AC02-76SF00515 RP-ID : 901853 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
The BaBar electromagnetic calorimeter energy calibration method was compared with the local and global peak iteration procedures, of Crystal Barrel and CLEO-II. An investigation was made of the possibility of {Upsilon}(4S) background reduction which could lead to increased statistics over a shorter time interval, for efficient calibration runs. The BaBar software package was used with unreconstructed data to study the energy response of the calorimeter, by utilizing the {pi}{sup 0} mass constraint on pairs of photon clusters.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
901853.pdf | 1250KB | download |