科技报告详细信息
A High-Efficiency Resonant Cavity for Measurement of a Beam Quadrupole Moment | |
Barov, N. ; Kim, J. S. ; Nantista, C. D. ; Miller, R. H. | |
Stanford Linear Accelerator Center | |
关键词: Bypasses; Cavities; 43 Particle Accelerators; Geometry; Accelerators; | |
DOI : 10.2172/878032 RP-ID : SLAC-PUB-11540 RP-ID : AC02-76SF00515 RP-ID : 878032 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
Many particle accelerator applications can benefit from online pulse-by-pulse nonintercepting emittance measurement system. Recently, there has been much interest in performing such a measurement with a set of resonant quadrupole-mode cavities. This article explores a geometry to achieve an enhanced shunt impedance in such a cavity by adding a set of posts forming capacitive gaps near the beam pipe outer radius. For typical diagnostic cavity applications, a five-fold increase in shunt impedance can be obtained with this method. The effect of errors in cavity fabrication on the required mode structure are explored.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
878032.pdf | 175KB | download |