科技报告详细信息
Vibration Testing of Dallas/Maxim iButton Temperature Logger, Model DS1999L, for Flight Qualification on Captive Flight Test Unit?B (CFTU-B)
Jacobson, G ; Lavietes, A
Lawrence Livermore National Laboratory
关键词: Modifications;    Lawrence Livermore National Laboratory;    Testing;    Excitation;    Cruise Missiles;   
DOI  :  10.2172/877879
RP-ID  :  UCRL-TR-213144
RP-ID  :  W-7405-ENG-48
RP-ID  :  877879
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

This report documents the flight qualification testing of the Dallas/Maxim iButton temperature logger, model DS1922L, for internal mounting to the W80 Air Launched Cruise Missile (ALCM). A single test was performed utilizing a Labworks Inc. LW-140-110 electro-dynamic vibration system in Building 131, Room 2272, at Lawrence Livermore National Laboratory, Livermore, California. Two DS1922L temperature loggers were tested simultaneously, one horizontally and one vertically. The test consisted of random excitation in the vertical axis for 5-hours. The test spectrum used is a shaped random spectrum defined by the Boeing Company for flight qualification of all modifications flown on ALCM flight tests. The spectrum is defined from 10 to 2000 Hz with a 8.52 g RMS magnitude. The spectrum is given in Table 1 and shown graphically in Figure 1.1.

【 预 览 】
附件列表
Files Size Format View
877879.pdf 715KB PDF download
  文献评价指标  
  下载次数:22次 浏览次数:25次