科技报告详细信息
MEASUREMENT OF FRICTIONAL PRESSURE DIFFERENTIALS DURING A VENTILATION SURVEY
B.S. Prosser, PE ; I.M. Loomis, PE, PhD
United States. Department of Energy. Yucca Mountain Project Office.
关键词: 12 Management Of Radioactive Wastes, And Non-Radioactive Wastes From Nuclear Facilities;    Pressure Measurement;    Friction Factor;    Yucca Mountain;    32 Energy Conservation, Consumption, And Utilization;   
DOI  :  10.2172/841249
RP-ID  :  NA
RP-ID  :  NA
RP-ID  :  841249
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】
During the course of a ventilation survey, both airflow quantity and frictional pressure losses are measured and quantified. The measurement of airflow has been extensively studied as the vast majority of ventilation standards/regulations are tied to airflow quantity or velocity. However, during the conduct of a ventilation survey, measurement of airflow only represents half of the necessary parameters required to directly calculate the airway resistance. The measurement of frictional pressure loss is an often misunderstood and misapplied part of the ventilation survey. This paper compares the two basic methods of frictional pressure drop measurements; the barometer and the gauge and tube. Personal experiences with each method will be detailed along with the authors' opinions regarding the applicability and conditions favoring each method.
【 预 览 】
附件列表
Files Size Format View
841249.pdf 1614KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:83次