科技报告详细信息
Radiation shielding calculations for MuCool test area at Fermilab | |
Rakhno, Igor ; Johnstone, Carol | |
Fermi National Accelerator Laboratory | |
关键词: 08 Hydrogen; 43 Particle Accelerators; Muon Beams; Shielding; Targets; | |
DOI : 10.2172/824355 RP-ID : FERMILAB-TM-2248 RP-ID : AC02-76CH03000 RP-ID : 824355 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
The MuCool Test Area (MTA) is an intense primary beam facility derived directly from the Fermilab Linac to test heat deposition and other technical concerns associated with the liquid hydrogen targets being developed for cooling intense muon beams. In this shielding study the results of Monte Carlo radiation shielding calculations performed using the MARS14 code for the MuCool Test Area and including the downstream portion of the target hall and berm around it, access pit, service building, and parking lot are presented and discussed within the context of the proposed MTA experimental configuration.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
824355.pdf | 317KB | download |