科技报告详细信息
Radiation shielding issues for MuCool test area at Fermilab
Rakhno, I. ; Johnstone, C. ; /Fermilab
Fermi National Accelerator Laboratory
关键词: Targets Accelerators;    Origin;    08 Hydrogen;    43 Particle Accelerators;    Muon Beams;   
DOI  :  10.2172/15017208
RP-ID  :  FERMILAB-TM-2305-AD
RP-ID  :  AC02-76CH03000
RP-ID  :  15017208
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The MuCool Test Area (MTA) is an intense primary beam facility derived directly from the Fermilab Linac to test heat deposition and other technical concerns associated with the liquid hydrogen targets being developed for cooling intense muon beams. In this study the origin of the outgoing collimated neutron beam is examined. An alternative shielding option for MTA is investigated as well as the hypothetical worst case of experimental setup is considered.

【 预 览 】
附件列表
Files Size Format View
15017208.pdf 721KB PDF download
  文献评价指标  
  下载次数:12次 浏览次数:23次