科技报告详细信息
GASIFICATION TEST RUN TC06
Southern Company Services, Inc.
Southern Company Services, Inc. (United States)
关键词: Modifications;    Particulates;    Tuning;    01 Coal, Lignite, And Peat;    Gasification;   
DOI  :  10.2172/822936
RP-ID  :  NONE
RP-ID  :  FC21-90MC25140
RP-ID  :  822936
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

This report discusses test campaign TC06 of the Kellogg Brown & Root, Inc. (KBR) Transport Reactor train with a Siemens Westinghouse Power Corporation (Siemens Westinghouse) particle filter system at the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama. The Transport Reactor is an advanced circulating fluidized-bed reactor designed to operate as either a combustor or a gasifier using a particulate control device (PCD). The Transport Reactor was operated as a pressurized gasifier during TC06. Test run TC06 was started on July 4, 2001, and completed on September 24, 2001, with an interruption in service between July 25, 2001, and August 19, 2001, due to a filter element failure in the PCD caused by abnormal operating conditions while tuning the main air compressor. The reactor temperature was varied between 1,725 and 1,825 F at pressures from 190 to 230 psig. In TC06, 1,214 hours of solid circulation and 1,025 hours of coal feed were attained with 797 hours of coal feed after the filter element failure. Both reactor and PCD operations were stable during the test run with a stable baseline pressure drop. Due to its length and stability, the TC06 test run provided valuable data necessary to analyze long-term reactor operations and to identify necessary modifications to improve equipment and process performance as well as progressing the goal of many thousands of hours of filter element exposure.

【 预 览 】
附件列表
Files Size Format View
822936.pdf 16419KB PDF download
  文献评价指标  
  下载次数:4次 浏览次数:17次