科技报告详细信息
A DEVELOPMENT OF ON-LINE TEMPERATURE MEASUREMENT INSTRUMENTATION FOR GASIFICATION PROCESS CONTROL
Noel, Bruce W.
Fluorescience (United States)
关键词: Calibration;    Signal-To-Noise Ratio;    Wavelengths;    Fibers;    Process Control;   
DOI  :  10.2172/813681
RP-ID  :  NONE
RP-ID  :  FC26-99FT40686
RP-ID  :  813681
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

This progress report covers continuing work to develop a temperature probe for a coal gasifier. A workable probe design requires finding answers to crucial questions involving the probe materials. We report on attempts to answer those questions. We attempted to measure the laser-input power at a wavelength of 355 nm that would damage the ends of sapphire fiber optics. We were surprised and pleased to learn that they survived an input power density of about 3 x 10{sup 9} W/cm{sup 2}, which greatly exceeds the best that fused-silica fibers can do. During a run of our new simulator to obtain an upgraded calibration curve for the improved YAG:Dy phosphors, we found that the phosphor appeared to form a eutectic, with the fused-silica cuvette used to hold the phosphor, when the temperature exceeded 1450 C. This result could have substantial ramifications in this and other high-temperature applications. Our new proprietary detector package that replaced the original photomultiplier tube gave excellent results, with much better signal-to-noise ratio at a given temperature than the old package. Our new plasma-spraying operation has succeeded in spraying YAG, which we think may be a technological breakthrough.

【 预 览 】
附件列表
Files Size Format View
813681.pdf 21KB PDF download
  文献评价指标  
  下载次数:9次 浏览次数:28次