科技报告详细信息
| Axial Pressure Drop Measurements during Pilot-Scale Testing of a Mott Crossflow Filter | |
| Poirier, M.R. | |
| Savannah River Site (S.C.) | |
| 关键词: Removal; Sludges; 12 Management Of Radioactive Wastes, And Non-Radioactive Wastes From Nuclear Facilities; Actinides; Filters; | |
| DOI : 10.2172/810990 RP-ID : WSRC-TR-2003-00051 RP-ID : AC09-96SR18500 RP-ID : 810990 |
|
| 美国|英语 | |
| 来源: UNT Digital Library | |
PDF
|
|
【 摘 要 】
The Department of Energy selected caustic side solvent extraction (CSSX) as the preferred cesium removal technology for Savannah River Site waste. As a pretreatment step for the CSSX flowsheet, personnel contact the incoming salt solution that contains entrained sludge with monosodium titanate (MST) to adsorb strontium and select actinides. They filter the resulting slurry to remove the sludge and MST. The conclusions from this work is detailed in this report.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 810990.pdf | 1737KB |
PDF