Final MTI Data Report: Comanche Peak Steam Electric Station | |
Parker, M.J. | |
Savannah River Site (S.C.) | |
关键词: Surface Waters; Streams; Monitoring; Personnel; Texas; | |
DOI : 10.2172/809089 RP-ID : WSRC-TR-2002-00374 RP-ID : AC09-96SR18500 RP-ID : 809089 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
During the periods from May 2000 to September 2001 and March 5 to April 10, 2002, cooling-lake surface water temperature data was collected at the Comanche Peak Nuclear Power Station near Granbury, Texas. This effort was led by the Savannah River Technology Center (SRTC) with the assistance of plant personnel. Permission for setting up these monitoring sites was granted by TXU Energy, which owns the plant site and surrounding property including Squaw Creek reservoir where the measurements were taken. This work was done in support of SRTC's ground truth mission for the U.S. Department of Energy's Multispectral Thermal Imager (MTI) satellite.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
809089.pdf | 5278KB | download |