Multi Canister Overpack (MCO) Combustible Gas Management Leak Test Acceptance Criteria (OCRWM) | |
SHERRELL, D.L. | |
Fluor Hanford, Inc. | |
关键词: Mco; Image Storage Tubes; Management; Electron Tubes; Air; | |
DOI : 10.2172/805625 RP-ID : HNF-2155, Rev.2 RP-ID : AC06-96RL13200 RP-ID : 805625 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
The purpose of this document is to support the Spent Nuclear Fuel Project's combustible gas management strategy while avoiding the need to impose any requirements for oxygen free atmospheres within storage tubes that contain multi-canister overpacks (MCO). In order to avoid inerting requirements it is necessary to establish and confirm leak test acceptance criteria for mechanically sealed and weld sealed MCOs that are adequte to ensure that, in the unlikely event the leak test results for any MCO were to approach either of those criteria, it could still be handled and stored in stagnant air without compromising the SNF Project's overall strategy to prevent accumulation of combustible gas mixtures within MCOs or within their surroundings. To support that strategy, this document: (1) establishes combustible gas management functions and minimum functional requirements for the MCO's mechanical seals and closure weld(s); (2) establishes a maximum practical value for the minimum required initial MCO inert backfill gas pressure; and (3) based on items 1 and 2, establishes and confirms leak test acceptance criteria for the MCO's mechanical seal and final closure weld(s).
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
805625.pdf | 4094KB | download |