科技报告详细信息
1999 Annual Cathodic Protection Survey Report for PFP
BOWMAN, T.J.
CH2M Hill Hanford Group, Inc.
关键词: Recommendations;    Pipes;    Performance Testing;    11 Nuclear Fuel Cycle And Fuel Materials;    Nuclear Facilities;   
DOI  :  10.2172/805367
RP-ID  :  HNF-7099, Rev.0
RP-ID  :  AC06-96RL13200
RP-ID  :  805367
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

This cathodic protection (CP) report documents the results of the 1999 annual CP survey of the underground piping within PFP property. An annual survey of CP systems is required by Washington Administrative Code (WAC). A spreadsheet to document the 1999 annual survey polarization data is included in this report. Graphs are included to trend the cathodic voltages and the polarization voltages at each test station on PFP property. The trending spans from 1994 to 1999. Graphs are also included to trend voltage and amperage outputs of each rectifier during the annual surveys. During the annual survey, resistance testing between the underground piping was conducted at each test station. The testing showed that all piping (with test leads into the test stations) was continuous with every pipe represented in the test stations. The resistance data is not documented in this report but can be accessed in work package 22-99-01003. During the annual survey, the wiring configurations of anode junction boxes AJB(R45-1) and AJB(45-1) were documented. The sketches can be accessed from the JCS work record of work package 22-99-01003. Analysis, conclusions, and recommendations of the 1999 annual CP survey results are included in this report.

【 预 览 】
附件列表
Files Size Format View
805367.pdf 3425KB PDF download
  文献评价指标  