科技报告详细信息
Final Report, FY 2001 200 East Vadose Test Site Hanford Washington Electrical Resistance Tomography
Ramirez, A. ; Daily, W. ; Binley, A.
Lawrence Livermore National Laboratory
关键词: Sodium;    Electrodes;    36 Materials Science;    58 Geosciences;    Thiosulfates;   
DOI  :  10.2172/802080
RP-ID  :  UCRL-ID-144655
RP-ID  :  W-7405-Eng-48
RP-ID  :  802080
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

This report covers the electrical resistance tomography (ERT) work performed at the Hanford Reservation, 200 East Area Vadose test (Sisson and Lu) site during the period March 23 through May 5,2001. The purposes of the ERT work were to: (1) Compare and contrast the development of the highly concentrated sodium thiosulfate plume (FY 01 work) with the fresh river water plume observed during FY 00. (2) Use the resistance images to infer the dynamics of the plume during two or three of the sodium thio-sulfate releases and during the water ''chaser'' release. (3) Determine the influence of the site's steel casings on the ability to construct reliable ERT images. (4) Determine if the steel casings at the site can be used as long electrodes to provide useful images of at least one release. (5) Develop quantitative estimates of the noise in the data and its effect on reconstructed images. Eleven electrode arrays (nine electrodes arrays available for the FY00 work), each with 15 electrodes, were installed at the site. These were used to perform 3D surveys before, during, and after 3 different spills.

【 预 览 】
附件列表
Files Size Format View
802080.pdf 9103KB PDF download
  文献评价指标  