科技报告详细信息
On-Line/At-Line Technetium Monitor Using Scintillating Ion Exchange Resins for the Savannah River Site | |
Wach, S.T. | |
Savannah River Site (S.C.) | |
关键词: Technetium 99; Ion Exchange; 38 Radiation Chemistry, Radiochemistry, And Nuclear Chemistry; Detection; Savannah River Plant; | |
DOI : 10.2172/761642 RP-ID : BNF-003-98-0130 RP-ID : AC09-96SR18500 RP-ID : 761642 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
The results of this study indicate that the combination of extraction chromatography and on-line flow-cell scintillation counting can exceed a 99Tc detection limit of 0.005 Ci/mL in the presence of 90Sr, 137Cs, and 239Pu in less than an 18 minute analysis time.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
761642.pdf | 930KB | download |