科技报告详细信息
Flash X-Ray Injector Study
Paul, A C
Lawrence Livermore National Laboratory
关键词: 43 Particle Accelerators;    Phase Space;    Cathodes;    Probes;    Anodes;   
DOI  :  10.2172/15009822
RP-ID  :  UCRL-TR-203991
RP-ID  :  W-7405-ENG-48
RP-ID  :  15009822
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The study described in this report1 models the FXR injector from the cathode to the exit of the injector. The calculations are compared to actual experimental measurements, table 1. In these measurements the anode voltage was varied by changing the Marks-Bank charging voltage. The anode-cathode spacing was varied by adjusting the location of the cathode in hopes of finding an island of minimum emittance (none found). The bucking coil current was set for zero field on the cathode. In these measurements, a pepper-pot mask was inserted into FXR at beam bug 135 and viewed downstream via a wiggle probe diagnostic at cell gap J21, figure 1. The observed expansion of the beamlets passing through the mask of known geometric layout and hole size allow a calculation of the phase space beam properties.

【 预 览 】
附件列表
Files Size Format View
15009822.pdf 3037KB PDF download
  文献评价指标  
  下载次数:11次 浏览次数:6次