科技报告详细信息
| Summary of NOx Emissions Reduction from Biomass Cofiring | |
| Dayton, D. | |
| National Renewable Energy Laboratory (U.S.) | |
| 关键词: Biomass; Biopower; Biomass/Coal Cofiring; Biomass Power; 01 Coal, Lignite, And Peat; | |
| DOI : 10.2172/15000430 RP-ID : NREL/TP-510-32260 RP-ID : AC36-99-GO10337 RP-ID : 15000430 |
|
| 美国|英语 | |
| 来源: UNT Digital Library | |
PDF
|
|
【 摘 要 】
NOx emissions from commercial- and pilot-scale biomass/coal cofiring demonstrations are reduced as the percentage of energy supplied to the boiler by the biomass fuel is increased. This report attempts to provide a summary of the NO{sub x} emissions measured during recent biomass/coal cofiring demonstrations. These demonstrations were carried out at the commercial and pilot-scales. Commercial-scale tests were conducted in a variety of pulverized fuel boiler types including wall-fired, T-fired, and cyclone furnaces. Biomass input ranged up to 20% on a mass basis and 10% on an energy basis.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 15000430.pdf | 278KB |
PDF