Short-Term Test Results: Transitional Housing Energy Efficiency Retrofit in the Hot-Humid Climate
Sutherland, K. ; Martin, E.
National Renewable Energy Laboratory (U.S.)
关键词: Buildings;    Energy Efficient Retrofit;    Building America Partnership For Improved Residential Construction (Ba-Pirc);    Cost-Benefit Analysis;    Simulation True-Up;   
DOI  :  10.2172/1063693
RP-ID  :  DOE/GO-102013-3853
RP-ID  :  AC36-08GO28308
RP-ID  :  1063693
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

This project evaluates the renovation of a 5,800 ft2, multi-use facility located in St. Petersburg, on the west coast of central Florida, in the hot humid climate. An optimal package of retrofit measures was designed to deliver 30-40% annual energy cost savings for this building with annual utility bills exceeding $16,000 and high base load consumption. Researchers projected energy cost savings for potential retrofit measures based on pre-retrofit findings and disaggregated, weather normalized utility bills as a basis for simulation true-up. A cost-benefit analysis was conducted for the seven retrofit measures implemented; adding attic insulation and sealing soffits, tinting windows, improving whole building air-tightness, upgrading heating and cooling systems and retrofitting the air distribution system, replacing water heating systems, retrofitting lighting, and replacing laundry equipment. The projected energy cost savings for the full retrofit package based on a post-retrofit audit is 35%. The building's architectural characteristics, vintage, and residential and commercial uses presented challenges for both economic projections and retrofit measure construction.

【 预 览 】
附件列表
Files Size Format View
1063693.pdf 1457KB PDF download
  文献评价指标  
  下载次数:21次 浏览次数:7次