| Initial test results from the RedFlow 5 kW, 10 kWh zinc-bromide module, phase 1. | |
| Ferreira, Summer Rhodes ; Rose, David Martin | |
| Sandia National Laboratories | |
| 关键词: 25 Energy Storage; Manufacturers; Capacity; Specifications; Efficiency; | |
| DOI : 10.2172/1039005 RP-ID : SAND2012-1352 RP-ID : AC04-94AL85000 RP-ID : 1039005 |
|
| 美国|英语 | |
| 来源: UNT Digital Library | |
PDF
|
|
【 摘 要 】
In this paper the performance results of the RedFlow zinc-bromide module (ZBM) Gen 2.0 are reported for Phase 1 of testing, which includes initial characterization of the module. This included physical measurement, efficiency as a function of charge and discharge rates, efficiency as a function of maximum charge capacity, duration of maximum power supplied, and limited cycling with skipped strip cycles. The goal of this first phase of testing was to verify manufacturer specifications of the zinc-bromide flow battery. Initial characterization tests have shown that the ZBM meets the manufacturer's specifications. Further testing, including testing as a function of temperature and life cycle testing, will be carried out during Phase 2 of the testing, and these results will be issued in the final report, after Phase 2 testing has concluded.