科技报告详细信息
ANALYSIS OF HARRELL MONOSODIUM TITANATE LOT #120111
Shehee, T.
Savannah River Site (S.C.)
关键词: Removal;    Actinides;    Specifications;    Sampling;    Verification;   
DOI  :  10.2172/1038049
RP-ID  :  SRNL-STI-2012-00075
RP-ID  :  DE-AC09-08SR22470
RP-ID  :  1038049
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】
Monosodium titanate (MST) for use in the Actinide Removal Process (ARP) must be qualified and verified in advance. A single qualification sample for each batch of material is sent to SRNL for analysis, as well as a statistical sampling of verification samples. The Harrell Industries Lot No.120111 qualification and the first 12 verification samples met all the requirements in the specification indicating the material is acceptable for use in the process. Analyses of Pail 125 verification sample fails the criteria for solids content and has measurably lower pH, density, and total bottle weight. The verification sample for Pail 125 was retested for weight percent solids after checking that all of the solids had been suspended. The sample again failed to meet acceptance criteria. SRNL recommends accepting Pails 1 through 120. Pails 121 through 125 should be rejected and returned to the vendor.
【 预 览 】
附件列表
Files Size Format View
1038049.pdf 92KB PDF download
  文献评价指标  