科技报告详细信息
SMALL-SCALE SAFETY TEST REPORT FOR RDX (SECOND CALIBRATION)
HSU, P C ; Reynolds, J G ; HSU, P C ; Reynolds, J G
Lawrence Livermore National Laboratory
关键词: Calibration;    Testing;    Resistors;    Electrostatics;    Lanl;   
DOI  :  10.2172/1022893
RP-ID  :  LLNL-TR-480177
RP-ID  :  W-7405-ENG-48
RP-ID  :  1022893
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

RDX was provided by Indian Head and was dried at 60 C for 16 hours, cooled and kept in a desiccator before use. Please note that the impact testing was done on both pellets and loose powder which resulted in different data. The impact sensitivity on pressed pellets was 34 cm that is greater than that on loose powder, as expected. The impact test data on the loose powder was similar to what Indian Head and LANL got. Remarkable consistent results were observed for test results of loose powder RDX. The average impact sensitivyt (DH{sub 50}) was 21.8 cm and the average friction sensitivity (F{sub 50}) for loose powder was 24.9 kg, respectively. DSC charts showed that peak temperatures and onset temperatures for all 3 runs of RDX samples were almost identical. All electrostatic spark sensitivity was 0/10 at 1.0 J with a 510-ohm resistor in the discharge circuit.

【 预 览 】
附件列表
Files Size Format View
1022893.pdf 3259KB PDF download
  文献评价指标  
  下载次数:16次 浏览次数:21次