科技报告详细信息
High-Temperature Motor Windings for Downhole Pumps Used in Geothermal Energy Production
Hooker, Matthew ; Hazelton, Craig ; Kano, Kimi
Composite Technology Development, Inc.
关键词: Electrical Insulation, Composite Insulation, Electric Submersible Pumps, Geothermal Energy;    Breakdown;    Geothermal Energy;    36 Materials Science;    Dielectric Materials;   
DOI  :  10.2172/1011754
RP-ID  :  DOE/GO/18183-1
RP-ID  :  FG36-08GO18183
RP-ID  :  1011754
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】
The development of highly reliable downhole equipment is an essential element in enabling the widespread utilization of Enhanced Geothermal Systems (EGS). The downhole equipment used in these systems will be required to operate at high voltages and temperatures on the order of 200 to 250°C (and eventually to 300˚C). These conditions exceed the practical operating ranges of currently available thermoplastic wire insulations, and thus limit the operating lifetime of tools such as Electric Submersible Pumps (ESPs). In this work, high-temperature insulations based on composite materials were developed and demonstrated. The products of this work were found to exhibit electrical resistivities and dielectric breakdown strengths that PEEK at temperatures above 250C. In addition, sub-scale motor windings were fabricated and tested to validate the performance of this technology
【 预 览 】
附件列表
Files Size Format View
1011754.pdf 989KB PDF download
  文献评价指标  
  下载次数:11次 浏览次数:33次