科技报告详细信息
A Self-Calibrating Remote Control Chemical Monitoring System
Jessica Croft
关键词: CHEMICAL ANALYSIS;    COMMUNICATIONS;    DESIGN;    MAINTENANCE;    MINERAL WASTES;    MINING;    MONITORING;    MONITORS;    REMOTE CONTROL;    STREAMS;    US EPA;    US SUPERFUND;    WATER;    WATER SUPPLY database backed website;    LabVIEW;   
DOI  :  10.2172/912463
RP-ID  :  INL/EXT-07-12890
PID  :  OSTI ID: 912463
Others  :  TRN: US200801%%893
学科分类:能源(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】
The Susie Mine, part of the Upper Tenmile Mining Area, is located in Rimini, MT about 15 miles southwest of Helena, MT. The Upper Tenmile Creek Mining Area is an EPA Superfund site with 70 abandoned hard rock mines and several residential yards prioritized for clean up. Water from the Susie mine flows into Tenmile Creek from which the city of Helena draws part of its water supply. MSE Technology Applications in Butte, Montana was contracted by the EPA to build a treatment system for the Susie mine effluent and demonstrate a system capable of treating mine waste water in remote locations. The Idaho National Lab was contracted to design, build and demonstrate a low maintenance self-calibrating monitoring system that would monitor multiple sample points, allow remote two-way communications with the control software and allow access to the collected data through a web site. The Automated Chemical Analysis Monitoring (ACAM) system was installed in December 2006. This thesis documents the overall design of the hardware, control software and website, the data collected while MSE-TA’s system was operational, the data collected after MSE-TA’s system was shut down and suggested improvements to the existing system.
【 预 览 】
附件列表
Files Size Format View
RO201705190001735LZ 2071KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:55次