科技报告详细信息
Area Monitoring Dosimeter Program for the Pacific Northwest National Laboratory: Results for CY 2006
Bivins, Steven R. ; Stoetzel, Gregory A.
关键词: DOSEMETERS;    RADIATION MONITORING;    PERSONNEL DOSIMETRY;    BATTELLE PACIFIC NORTHWEST LABORATORIES;   
DOI  :  10.2172/912725
RP-ID  :  PNNL-16704
PID  :  OSTI ID: 912725
Others  :  TRN: US0800436
学科分类:核能源与工程
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】
Pacific Northwest National Laboratory (PNNL) established an area monitoring dosimeter program in accordance with Article 514 of the Department of Energy (DOE) Radiological Control Manual (RCM) in January 1993. This program is to minimize the number of areas requiring issuance of personnel dosimeters and to demonstrate that doses outside Radiological Buffer Areas are negligible. In accordance with 10 CFR Part 835.402 (a)(1)-(4) and Article 511.1 of the PNNL Radiological Control Program Description, personnel dosimetry shall be provided to 1) radiological workers who are likely to receive at least 100 mrem annually, and 2) declared pregnant workers, minors, and members of the public who are likely to receive at least 50 mrem annually. Program results for calendar years 1993-2005 confirm that personnel dosimetry is not needed for individuals located in areas monitored by the program.
【 预 览 】
附件列表
Files Size Format View
RO201705190001421LZ 240KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:12次