科技报告详细信息
| Sandia National Laboratories results for the 2010 criticality accident dosimetry exercise, at the CALIBAN reactor, CEA Valduc France. | |
| Ward, Dann C. | |
| 关键词: CRITICALITY; DOSEMETERS; PERSONNEL DOSIMETRY; NEUTRONS; ORIENTATION; PHANTOMS; RADIATION ACCIDENTS; SANDIA NATIONAL LABORATORIES; | |
| DOI : 10.2172/1029804 RP-ID : SAND2011-6416 PID : OSTI ID: 1029804 Others : TRN: US1200047 |
|
| 学科分类:核能源与工程 | |
| 美国|英语 | |
| 来源: SciTech Connect | |
PDF
|
|
【 摘 要 】
This document describes the personal nuclear accident dosimeter (PNAD) used by Sandia National Laboratories (SNL) and presents PNAD dosimetry results obtained during the Nuclear Accident Dosimeter Intercomparison Study held 20-23 September, 2010, at CEA Valduc, France. SNL PNADs were exposed in two separate irradiations from the CALIBAN reactor. Biases for reported neutron doses ranged from -15% to +0.4% with an average bias of -7.7%. PNADs were also exposed on the back side of phantoms to assess orientation effects.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO201704210001227LZ | 1152KB |
PDF