CH Packaging Program Guidance
关键词: TRUPACT-II;    HalfPACT;    Safety Analysis Report;    annual maintenance;    bench stock;    Certificate of Compliance;    certified waste;    O-ring;    contact-handled;    leak check;    leakage rate;    mobile loading unit;    nonconformance report;    out-of-service;    package;    packaging;    periodic leakage rate;    preshipment;    safety analysis report for packaging;    transuranic;    transuranic content codes;    TRAMPAC.;   
DOI  :  10.2172/988283
RP-ID  :  DOE/WIPP--02-3183,Rev.6
PID  :  OSTI ID: 988283
学科分类:核能源与工程
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】
The purpose of this document is to provide the technical requirements for preparation for use, operation, inspection, and maintenance of a Transuranic Package Transporter Model II (TRUPACT-II), a HalfPACT shipping package, and directly related components. This document complies with the minimum requirements as specified in the TRUPACT-II Safety Analysis Report for Packaging (SARP), HalfPACT SARP, and U.S. Nuclear Regulatory Commission (NRC) Certificates of Compliance (C of C) 9218 and 9279, respectively. In the event of a conflict between this document and the SARP or C of C, the C of C shall govern. The C of Cs state: "each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the pplication." They further state: "each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application." Chapter 9.0 of the SARP charges the U.S. Department of Energy (DOE) or the Waste Isolation Pilot Plant (WIPP) management and operating (M&O) contractor with assuring packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations (CFR) §71.8. Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required. In accordance with 10 CFR Part 71, certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21 regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to these regulations are conducted. This document provides the instructions to be followed to operate, maintain, and test the TRUPACT-II and HalfPACT packaging. The intent of these instructions is to standardize operations. All users will follow these instructions or equivalent instructions that assure operations are safe and meet the requirements of the SARPs.
【 预 览 】
附件列表
Files Size Format View
RO201705180000017LZ 454KB PDF download
  文献评价指标  
  下载次数:15次 浏览次数:60次