科技报告详细信息
| Tests of Coordinate Transfer from Magnetic to Mechanical Reference for LCLS Undulator Fiducialization | |
| Levashov, Yu. | |
| 关键词: ALGORITHMS; CALIBRATION; QUADRUPOLES; WIGGLER MAGNETS; LIGHT SOURCES; FREE ELECTRON LASERS; LINEAR ACCELERATORS; MEASURING METHODS; PERFORMANCE XFEL; | |
| DOI : 10.2172/1000390 RP-ID : SLAC-TN-10-088 PID : OSTI ID: 1000390 Others : TRN: US1100102 |
|
| 美国|英语 | |
| 来源: SciTech Connect | |
PDF
|
|
【 摘 要 】
Fiducialization of the LCLS undulators will be based on magnetic measurements by Hall probe. Pointed magnets, proposed by I.Vasserman for quadrupole lens fiducialization will be used as an intermediate reference. A prototype of the pointed magnet fixture has been made and tested. In this note we will describe a procedure for measuring the position of the center of the Hall probe sensitive area with respect to the undulator fiducial marks. The pointed magnet calibration procedure, a two-point algorithm for locating the magnetic center of the fixture, and test results are presented.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO201704240000148LZ | 1454KB |
PDF