LIQUID AIR INTERFACE CORROSION TESTING FOR FY2010
Zapp, P.
关键词: AR FACILITIES;    AIR;    CARBON;    CARBON DIOXIDE;    CARBON STEELS;    CORROSION;    LIQUID WASTES;    RADIOACTIVE WASTE STORAGE;    RADIOACTIVE WASTES;    TANKS;    TESTING;    THIN FILMS;   
DOI  :  10.2172/1001187
RP-ID  :  SRNL-STI-2010-00573
PID  :  OSTI ID: 1001187
Others  :  TRN: US1100441
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】
An experimental study was undertaken to investigate the corrosivity to carbon steel of the liquid-air interface of dilute simulated radioactive waste solutions. Open-circuit potentials were measured on ASTM A537 carbon steel specimens located slightly above, at, and below the liquid-air interface of simulated waste solutions. The 0.12-inch-diameter specimens used in the study were sized to respond to the assumed distinctive chemical environment of the liquid-air interface, where localized corrosion in poorly inhibited solutions may frequently be observed. The practical inhibition of such localized corrosion in liquid radioactive waste storage tanks is based on empirical testing and a model of a liquid-air interface environment that is made more corrosive than the underlying bulk liquid due to chemical changes brought about by absorbed atmospheric carbon dioxide. The chemical changes were assumed to create a more corrosive open-circuit potential in carbon in contact with the liquid-air interface. Arrays of 4 small specimens spaced about 0.3 in. apart were partially immersed so that one specimen contacted the top of the meniscus of the test solution. Two specimens contacted the bulk liquid below the meniscus and one specimen was positioned in the vapor space above the meniscus. Measurements were carried out for up to 16 hours to ensure steady-state had been obtained. The results showed that there was no significant difference in open-circuit potentials between the meniscus-contact specimens and the bulk-liquid-contact specimens. With the measurement technique employed, no difference was detected between the electrochemical conditions of the meniscus versus the bulk liquid. Stable open-circuit potentials were measured on the specimen located in the vapor space above the meniscus, showing that there existed an electrochemical connection through a thin film of solution extending up from the meniscus. This observation supports the Hobbs-Wallace model of the development of the pitting susceptibility of carbon steel in alkaline solutions.
【 预 览 】
附件列表
Files Size Format View
RO201704240000129LZ 330KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:37次