科技报告详细信息
Neutron counting and gamma spectroscopy with PVT detectors.
Mitchell, Dean James ; Brusseau, Charles A.
关键词: CAPTURE;    DETECTION;    GAMMA SPECTROSCOPY;    MONITORS;    NEUTRON DETECTION;    NEUTRON DETECTORS;    NEUTRON REACTIONS;    NEUTRON SOURCES;    NEUTRONS;    POLYETHYLENES;    POLYVINYLS;    PVC;    RADIATIONS;    RESOLUTION;    SECURITY;    SENSITIVITY;    SENSORS;    SPECTRA;    STABILITY;    TOLUENE;    TRADE;   
DOI  :  10.2172/1020503
RP-ID  :  SAND2011-4361
PID  :  OSTI ID: 1020503
Others  :  TRN: US1103820
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】
Radiation portals normally incorporate a dedicated neutron counter and a gamma-ray detector with at least some spectroscopic capability. This paper describes the design and presents characterization data for a detection system called PVT-NG, which uses large polyvinyl toluene (PVT) detectors to monitor both types of radiation. The detector material is surrounded by polyvinyl chloride (PVC), which emits high-energy gamma rays following neutron capture reactions. Assessments based on high-energy gamma rays are well suited for the detection of neutron sources, particularly in border security applications, because few isotopes in the normal stream of commerce have significant gamma ray yields above 3 MeV. Therefore, an increased count rate for high-energy gamma rays is a strong indicator for the presence of a neutron source. The sensitivity of the PVT-NG sensor to bare {sup 252}Cf is 1.9 counts per second per nanogram (cps/ng) and the sensitivity for {sup 252}Cf surrounded by 2.5 cm of polyethylene is 2.3 cps/ng. The PVT-NG sensor is a proof-of-principal sensor that was not fully optimized. The neutron detector sensitivity could be improved, for instance, by using additional moderator. The PVT-NG detectors and associated electronics are designed to provide improved resolution, gain stability, and performance at high-count rates relative to PVT detectors in typical radiation portals. As well as addressing the needs for neutron detection, these characteristics are also desirable for analysis of the gamma-ray spectra. Accurate isotope identification results were obtained despite the common impression that the absence of photopeaks makes data collected by PVT detectors unsuitable for spectroscopic analysis. The PVT detectors in the PVT-NG unit are used for both gamma-ray and neutron detection, so the sensitive volume exceeds the volume of the detection elements in portals that use dedicated components to detect each type of radiation.
【 预 览 】
附件列表
Files Size Format View
RO201704210002108LZ 501KB PDF download
  文献评价指标  
  下载次数:24次 浏览次数:20次