科技报告详细信息
Integrated Data Collection Analysis (IDCA) Program - RDX Standard Data Set 2
Sandstrom, Mary M.1  Brown, Geoffrey W.1  Preston, Daniel N.1 
[1] Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
关键词: small-scale safety testing;    proficiency test;    impact-;    friction-;    spark discharge-;    thermal testing;    round-robin test;    safety testing protocols;    HME;    RDX;    potassium perchlorate;    potassium chlorate;    sodium chlorate;    sugar;    dodecane;    PETN;    carbon;   
DOI  :  10.2172/1305884
RP-ID  :  LLNL-TR--619637
PID  :  OSTI ID: 1305884
学科分类:化学(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Type II Class 5 standard, from testing the second time in the Proficiency Test. This RDX testing (Set 2) compared to the first (Set 1) was found to have about the same impact sensitivity, have more BAM friction sensitivity, less ABL friction sensitivity, similar ESD sensitivity, and same DSC sensitivity.

【 预 览 】
附件列表
Files Size Format View
RO201704180004114LZ 1998KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:60次