科技报告详细信息
Integrated Data Collection Analysis (IDCA) Program ??? RDX Standard Data Sets
Sandstrom, Mary M.1  Brown, Geoffrey W.1  Preston, Daniel N.1 
[1] Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
关键词: small-scale safety testing;    proficiency test;    impact-;    friction-;    spark discharge-;    thermal testing;    round-robin test;    safety testing protocols;    HME;    RDX;    potassium perchlorate;    potassium chlorate;    sodium chlorate;    sugar;    dodecane;    PETN;    carbon;   
DOI  :  10.2172/1305832
RP-ID  :  LLNL-TR--624214
PID  :  OSTI ID: 1305832
学科分类:化学(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Type II Class 5 standard, for a third and fourth time in the Proficiency Test and averaged with the analysis results from the first and second time. The results, from averaging all four sets (1, 2, 3 and 4) of data suggest a material to have slightly more impact sensitivity, more BAM friction sensitivity, less ABL friction sensitivity, similar ESD sensitivity, and same DSC sensitivity, compared to the results from Set 1, which was used previously as the values for the RDX standard in IDCA Analysis Reports.

【 预 览 】
附件列表
Files Size Format View
RO201704180003854LZ 1103KB PDF download
  文献评价指标  
  下载次数:13次 浏览次数:75次