Cold Climate Foundation Retrofit Energy Savings. The Simulated Energy and Experimental Hygrothermal Performance of Cold Climate Foundation Wall Insulation Retrofit Measures -- Phase I, Energy Simulation | |
Goldberg, Louise F.1  Steigauf, Brianna1  | |
[1] NorthernSTAR Building America Partnership, Minneapolis, MN (United States) | |
关键词: building foundations; energy simulation; beopt; energyplus; residential; residential building; building america; | |
DOI : 10.2172/1220005 RP-ID : DOE/GO--102013-3844 PID : OSTI ID: 1220005 Others : Other: 6212 |
|
美国|英语 | |
来源: SciTech Connect | |
【 摘 要 】
A split simulation whole building energy / 3-dimensional earth contact model (termed the BUFETS/EnergyPlus Model or BEM) capable of modeling the full range of foundation systems found in the target retrofit housing stock has been extensively tested. These foundation systems that include abovegrade foundation walls, diabatic floors or slabs as well as lookout or walkout walls, currently cannot be modeled within BEopt.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201704180003576LZ | 2201KB | download |