科技报告详细信息
Imagine Homes New Construction Occupied Test House
Stecher, D. ; Rapport, A. ; Allison, K.
关键词: ACH;    AIR CHANGES PER HOUR;    AFUE;    AMY;    ACTUAL METEOROLOGICAL YEAR;    ANNUAL FUEL UTILIZATION EFFICIENCY;    AHU;    AIR HANDLER UNIT;    BA;    BUILDING AMERICA;    BEOPT;    BUILDING ENERGY OPTIMIZATION;    HSP;    HOUSE SIMULATION PROTOCOLS;    HVAC;    HEATING;    VENTILATION;    AND AIR CONDITIONING;    LIGHTING;    APPLIANCES;    MISCELLANEOUS ELECTRIC LOADS;    RESIDENTIAL;    RESIDENTIAL BUILDING;    IBACOS;    BUILDING AMERICA;    Buildings;   
DOI  :  10.2172/1087795
RP-ID  :  DOE/GO-102013-3911
PID  :  OSTI ID: 1087795
Others  :  Other: KNDJ-0-40341-00
学科分类:能源(综合)
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

This report summarizes the research findings of a long-term monitoring plan to evaluate the performance of an energy-efficient home constructed in 2010 in San Antonio, Texas. Monitoring of the energy use, energy generation, and temperature conditions for this project occurred between July 2010 and October 2011. The heating, ventilation, and air conditioning system effectively maintained acceptable temperatures and humidity levels in peak cooling and heating and non-peak operating periods. Discrepancies were found between modeled and actual energy use values, with actual space cooling energy use closest to the corresponding modeled value. Energy consumption predicted for lighting, appliances, and miscellaneous electrical loads was significantly higher than measured amounts, and energy consumption predicted for cooling was significantly lower than measured amounts. A high amount of the 1,600 kWh of PV-generated electricity produced annually was sent to the electric grid every month. The solar thermal DHW system was the main source of hot water for most of the year and performed well; during summer, electrical use by the backup system was rare.

【 预 览 】
附件列表
Files Size Format View
RO201704180002408LZ 2921KB PDF download
  文献评价指标  
  下载次数:17次 浏览次数:44次