科技报告详细信息
Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System
Burdick, A.1 
[1] IBACOS, Inc., Pittsburgh, PA (United States)
关键词: compact duct system;    compact air distribution system;    heating;    ventilation;    and air conditioning (HVAC);    insulation;    reverse attic bulkhead;    plenum truss;   
DOI  :  10.2172/1221054
RP-ID  :  DOE/GO--102013-4017
PID  :  OSTI ID: 1221054
Others  :  Other: 6541
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

【 预 览 】
附件列表
Files Size Format View
RO201704180001079LZ 3226KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:17次