Simplified Space Conditioning in Low-Load Homes: Results from Pittsburgh, Pennsylvania, New Construction Unoccupied Test House | |
Poerschke, Andrew1  Stecher, Dave1  | |
[1] IBACOS, Inc., Pittsburgh, PA (United States) | |
关键词: June 2014; residential; Residential Buildings; IBACOS; Building America; field test results; room-to-room uniformity; mini-split; single point; heating; ventilation; and air conditioning (HVAC); Pittsburgh; Pennsylvania; new construction unoccupied test house; ACCA Manual RS; ASHRAE Standard 55; occupant comfort; space conditioning; 50% Building America Benchmark; cold climate; | |
DOI : 10.2172/1221035 RP-ID : DOE/GO--102014-4436 PID : OSTI ID: 1221035 Others : Other: 6831 |
|
美国|英语 | |
来源: SciTech Connect | |
【 摘 要 】
Field testing was performed in a new construction unoccupied test house in Pittsburgh, PA. Four air-based heating, ventilation, and air conditioning distribution systems???a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, a system with transfer fans to the bedrooms, and a system with no ductwork to the bedrooms???were evaluated during heating, cooling, and midseason conditions. The relative ability of each system was assessed with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability, respectively.