科技报告详细信息
ANALYTICAL RESULTS FOR MOX COLEMANITE CONCRETE SAMPLES RECEIVED ON SEPTEMBER 4, 2013
Reigel, M.
关键词: MOX;    Colemanite Concrete;   
DOI  :  10.2172/1132257
RP-ID  :  SRNL-STI-2013-00572
PID  :  OSTI ID: 1132257
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory (SRNL) is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. SRNL received three samples of colemanite concrete for analysis on September 4, 2013. The average total density of each of the samples measured by the ASTM method C 642, the average partial hydrogen density was measured using method ASTM E 1131, and the average partial boron density of each sample was measured according to ASTM C 1301. The lower limits and measured values for the total density, hydrogen partial density, and boron partial density are presented. For all the samples tested, the total density and the boron partial density met or exceeded the specified limit. None of the samples met the lower limit for hydrogen partial density.

【 预 览 】
附件列表
Files Size Format View
618KB PDF download
  文献评价指标  
  下载次数:21次 浏览次数:17次