关键词: residential;    Residential Buildings;    IBACOS;    Building America;    cathedralized attics;    unvented attics;    hygrothermal analysis;    moisture risk;    closed-cell spray foam insulation;    attic ventilation;    attic airflow paths (cracks);    attic air leakage;    moisture in unvented attics;    water vapor flow rate;    condensation;    humidity;    CONTAM;    WUFI;    BEopt;    CFD analysis;    cold climate;   
DOI  :  10.2172/1220378
RP-ID  :  DOE/GO--102014-4526
PID  :  OSTI ID: 1220378
Others  :  Other: 6976
美国|英语
来源: SciTech Connect
PDF
【 摘 要 】

IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through individual airflow (crack) paths, simulated hourly flow rates through the leakage paths with CONTAM software, correlated the CONTAM flow rates with indoor humidity ratios from Building Energy Optimization software, and used W?��rme und Feuchte instation?��r Pro two-dimensional modeling to determine the moisture content of the building materials surrounding the cracks. Given the number of simplifying assumptions and numerical models associated with this analysis, the results indicate that localized damage due to high moisture content of the roof sheathing is possible under very low airflow rates. Reducing the number of assumptions and approximations through field studies and laboratory experiments would be valuable to understand the real-world moisture damage potential in unvented attics.

【 预 览 】
附件列表
Files Size Format View
4221KB PDF download
  文献评价指标  
  下载次数:17次 浏览次数:49次