科技报告详细信息
| Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs | |
| Loomis, H.1  Pettit, B.1  | |
| [1] Building Science Corporation, Westford, MA (United States) | |
| 关键词: residential; Residential Buildings; BSC; Building America; Deep Energy Retrofit; Deep Energy Enclosure Retrofit; Enclosure Retrofit; retrofit; Flat Roof; | |
| DOI : 10.2172/1220467 RP-ID : DOE/GO--102015-4632 PID : OSTI ID: 1220467 Others : Other: 7080 |
|
| 美国|英语 | |
| 来源: SciTech Connect | |
PDF
|
|
【 摘 要 】
This Measure Guideline provides design and construction information for a deep energy enclosure retrofit (DEER) solution of a flat roof assembly. It describes the strategies and procedures for an exterior retrofit of a flat, wood-framed roof with brick masonry exterior walls, using exterior and interior (framing cavity) insulation. The approach supported in this guide could also be adapted for use with flat, wood-framed roofs with wood-framed exterior walls.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 5225KB |
PDF