| JACC-CARDIOVASCULAR IMAGING | 卷:13 |
| Diagnostic Accuracy of [11C]PIB Positron Emission Tomography for Detection of Cardiac Amyloidosis | |
| Article | |
| Rosengren, Sara1  Clemmensen, Tor Skibsted2  Tolbod, Lars3  Granstam, Sven-Olof4  Eiskjaer, Hans2  Wikstrom, Gerhard5  Vedin, Ola5  Kero, Tanja6  Lubberink, Mark6,7  Harms, Hendrik J.3  Flachskampf, Frank A.4  Baron, Tomasz4  Carlson, Kristina1  Mikkelsen, Fabian2  Antoni, Gunnar8  Andersen, Niels Frost9  Poulsen, Steen Hvitfeldt2  Sorensen, Jens3,6  | |
| [1] Uppsala Univ, Department Med Sci, Hematol, Uppsala, Sweden | |
| [2] Aarhus Univ Hosp, Dept Cardiol, Aarhus, Denmark | |
| [3] Aarhus Univ Hosp, Dept Nucl Med & PET, Aarhus, Denmark | |
| [4] Uppsala Univ, Clin Physiol, Dept Med Sci, Uppsala, Sweden | |
| [5] Uppsala Univ, Dept Med Sci, Cardiol, Uppsala, Sweden | |
| [6] Uppsala Univ, Dept Surg Sci, Radiol, Uppsala, Sweden | |
| [7] Uppsala Univ, Dept Med Phys, Uppsala, Sweden | |
| [8] Uppsala Univ, Dept Med Chem, Uppsala, Sweden | |
| [9] Aarhus Univ Hosp, Dept Hematol, Aarhus, Denmark | |
| 关键词: diagnosis; heart; nuclear imaging; PET; Pittsburgh compound B; | |
| DOI : 10.1016/j.jcmg.2020.02.023 | |
| 来源: Elsevier | |
PDF
|
|
【 摘 要 】
OBJECTIVES This dual-site study evaluated the diagnostic accuracy of the method. BACKGROUND Pittsburgh compound ([C-11]PIB) positron emission tomography (PIB-PET) has shown promise as a specific and noninvasive method for the diagnosis of cardiac amyloidosis (CA). METHODS The study had 2 parts. In the initial study, 51 subjects were included, 36 patients with known CA and increased wall thickness (15 immunoglobulin light chain [AL] and 21 transthyretin [ATTR] amyloidosis) and 15 control patients (7 were nonamyloid hypertrophic and 8 healthy volunteers). Subjects underwent PIB-PET and echocardiography. Sensitivity and specificity of PIB-PET were established for 2 simple semiquantitative approaches, standardized uptake value ratio (SUVR) and retention index (RI). The second part of the study included (11) amyloidosis patients (5 AL and 6 hereditary ATTR) without increased wall thickness to which the optimal cutoff values of SUVR (>1.09) and RI (>0.037 min-1) were applied prospectively. RESULTS The diagnostic accuracy of visual inspection of [C-11]PIB uptake was 100% in discriminating CA patients with increased wall thickness from controls. Semiquantitative [C-11]PIB uptake discriminated CA from controls with a 94% (95% confidence interval [CI]: 80% to 99%) sensitivity for both SUVR and RI and specificity of 93% (95% CI: 66% to 100%) for SUVR and 100% (95% CI: 75% to 100%) for RI. [C-11]PIB uptake was significantly higher in AL-CA than in ATTR-CA patients (p < 0.001) and discriminated AL-CA from controls with 100% (95% CI: 88% to 100%) accuracy for both the semiquantitative measures. In the prospective group without increased wall thickness, RI was elevated compared to controls (p = 0.001) and 5 of (11) subjects were evaluated as [C-11]PIB PET positive. CONCLUSIONS In a dual-center setting, [C-11]PIB PET was highly accurate in detecting cardiac involvement in the main amyloid subtypes, with 100% accuracy in AL amyloidosis. A proportion of amyloidosis patients without known cardiac involvement were [C-11]PIB PET positive, indicating that the method may detect early stages of CA. (c) 2020 by the American College of Cardiology Foundation.
【 授权许可】
Free
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 10_1016_j_jcmg_2020_02_023.pdf | 1204KB |
PDF