期刊论文详细信息
JOURNAL OF HAZARDOUS MATERIALS 卷:374
Electrocoagulation using stainless steel anodes: Simultaneous removal of phosphates, Orange II and zinc ions
Article
Dura, Adelaide1  Breslin, Carmel B.1 
[1] Maynooth Univ, Dept Chem, Maynooth, Kildare, Ireland
关键词: Electrocoagulation;    Stainless steel;    Chromium content;    Phosphates;    Dyes;    Zinc ions;   
DOI  :  10.1016/j.jhazmat.2019.04.032
来源: Elsevier
PDF
【 摘 要 】

Two stainless steel anodes, AISI 420 and AISI 310, and pure iron were compared in an electrocoagulation study for the simultaneous removal of phosphates, Orange II and Zinc ions from a synthetic wastewater at a current density of 11.7 mA cm(-2) and a surface area to volume ratio of 19.4 m(-1). High removal efficiencies were observed with AISI 420 and pure iron, reaching values between 88% and 99%, while significantly lower values, approximately 30%, were obtained with AISI 310. The AISI 310 performed well in the removal of Zn2+ due to its removal as Zn(OH)(2). The variations in the performance of the steel anodes were attributed to the lower chromium content of the AISI 420, which gives less passive behaviour. This was supported using polarisation data, where a 10-fold increase in the corrosion current was obtained for AISI 420 compared to AISI 310. Furthermore, Cr(VI) was observed in the solution phase when AISI 310 was employed as the anode, illustrating the importance of the alloying concentrations. While rust particles were seen during the non-continuous use of the iron anode, they were not observed with the AISI 420 anode.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_jhazmat_2019_04_032.pdf 1135KB PDF download
  文献评价指标  
  下载次数:4次 浏览次数:0次