期刊论文详细信息
JOURNAL OF CLEANER PRODUCTION 卷:189
Efficient removal of arsenate from oxic contaminated water by colloidal humic acid-coated goethite: Batch and column experiments
Article
Montalvo, Daniela1  Vanderschueren, Ruth1  Fritzsche, Andreas2  Meckenstock, Rainer U.3  Smolders, Erik1 
[1] Katholieke Univ Leuven, Div Soil & Water Management, Kasteelpk Arenberg, Heverlee, Belgium
[2] Friedrich Schiller Univ Jena, Inst Geowissensch, D-07749 Jena, Germany
[3] Univ Duisburg Essen, Biofilm Ctr, D-45141 Essen, Germany
关键词: Iron oxide colloids;    Humic acids;    Reactive barrier;    Arsenic adsorption;    Transport;    Coagulation;   
DOI  :  10.1016/j.jclepro.2018.04.055
来源: Elsevier
PDF
【 摘 要 】

Arsenic (As) contamination of groundwater frequently occurs and there is a need for cost-effective in situ remediation techniques. The injection of iron oxide colloids coated with humic substances has been proposed. This technology is based on injecting mobile humic acid-coated goethite colloids that are subsequently deposited by aggregation in the contaminated zone where the ionic strength is large, thereby creating an in situ reactive barrier for As. While coagulation and deposition are desirable for colloid immobilization, its effect on adsorption properties have been previously overlooked. This study was set up to investigate if i) humic acid-coated goethite colloids retain their As(V) adsorption properties after coagulation in quartz sand and ii) if batch As(V) adsorption data can predict As immobilization in columns at variable flow conditions. Equilibrium batch adsorption experiments showed that humic acid coated goethite colloids coagulated and deposited on quartz sand have equal As(V) adsorption capacity, but two-fold lower affinity than humic acid-goethite colloids in suspension. This results indicated that there were some interactions between the sand and colloids but the overall adsorption capacity was not affected. Column experiments using sand coated with humic acid-goethite colloids (2.80 mg goethite g(-1) sand) and stepwise injection of As(V) (1-4.9 mg As L-1) showed a highly efficient As(V) removal from the liquid phase as the outflow As(V) concentrations remained below the drinking water limit (10 mu g As L-1) until about 45% of the sorbent capacity (30 mg As g(-1) goethite) was reached. The flow rate dependent leachate As concentrations, including responses to stop-flow events, illustrated non-equilibrium sorption. The equilibrium batch adsorption parameters failed to predict the observed As(V) breakthrough curves, which were better fitted with a chemical non-equilibrium consideration. This study confirms the feasibility of the technology on lab-scale but suggests that safety factors must be embedded to account for As(V) by-pass flow that could occur during field applications. (C) 2018 Elsevier Ltd. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_jclepro_2018_04_055.pdf 1502KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:0次