| TALANTA | 卷:128 |
| Evaluation of the multi-element capabilities of collision/reaction cell inductively coupled plasma-mass spectrometry in wine analysis | |
| Article | |
| Grindlay, Guillermo1,2  Mora, Juan1  de Loos-Vollebregt, Margaretha T. C.2,3  Vanhaecke, Frank1  | |
| [1] Univ Alicante, Dept Analyt Chem Nutr & Food Sci, E-03080 Alicante, Spain | |
| [2] Univ Ghent, Dept Analyt Chem, B-9000 Ghent, Belgium | |
| [3] Delft Univ Technol, Fac Appl Sci Analyt Biotechnol, NL-2628 BC Delft, Netherlands | |
| 关键词: Spectral interference; Collision/reaction cell; ICP-MS; Multi-element analysis; Wine; | |
| DOI : 10.1016/j.talanta.2014.05.008 | |
| 来源: Elsevier | |
PDF
|
|
【 摘 要 】
This work explores the multi-element capabilities of inductively coupled plasma-mass spectrometry with collision/reaction cell technology (CCT-ICP-MS) for the simultaneous determination of both spectrally interfered and non-interfered nuclides in wine samples using a single set of experimental conditions. The influence of the cell gas type (i.e. He, He+H-2 and He+NH3), cell gas flow rate and sample pre-treatment (i.e. water dilution or acid digestion) on the background-equivalent concentration (BEC) of several nuclides covering the mass range from 7 to 238 u has been studied. Results obtained in this work show that, operating the collision/reaction cell with a compromise cell gas flow rate (i.e. 4 mL min(-1)) improves BEC values for interfered nuclides without a significant effect on the BECs for non-interfered nuclides, with the exception of the light elements Li and Be. Among the different cell gas mixtures tested, the use of He or He+H-2 is preferred over He+NH3 because NH3 generates new spectral interferences. No significant influence of the sample pre-treatment methodology (i.e. dilution or digestion) on the multi-element capabilities of CCT-ICP-MS in the context of simultaneous analysis of interfered and non-interfered nuclides was observed. Nonetheless, sample dilution should be kept at minimum to ensure that light nuclides could be quantified in wine. Finally, a direct 5-fold aqueous dilution is recommended for the simultaneous trace and ultra-trace determination of spectrally interfered and non-interfered elements in wine by means of CCT-ICP-MS. The use of the CCT is mandatory for interference-free ultra-trace determination of Ti and Cr. Only Be could not be determined when using the CCT due to a deteriorated limit of detection when compared to conventional ICP-MS. (C) 2014 Elsevier B.V. All rights reserved.
【 授权许可】
Free
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 10_1016_j_talanta_2014_05_008.pdf | 560KB |
PDF