A gas-diffusion flow injection method coupled with online solid-liquid extraction for the determination of ammonium in solid samples
Article
Timofeeva, Irina I.1,2  Bulatov, Andrey V.1  Moskvin, Aleksey L.1  Kolev, Spas D.2 
[1] St Petersburg State Univ, Inst Chem, Dept Analyt Chem, St Petersburg 19850, Russia
[2] Univ Melbourne, Sch Chem, Melbourne, Vic 3010, Australia
关键词: Flow injection analysis (FIA);    Gas-diffusion;    Solid-liquid extraction;    Leaching;    Ammonium;    Ammonia;    Building materials;   
DOI  :  10.1016/j.talanta.2015.04.051
来源: Elsevier
PDF
【 摘 要 】

A simple, rapid and reliable gas-diffusion flow injection (GD-FI) method for ammonium determination in building materials has been developed. It is based on leaching ammonium from a ground solid sample into an alkaline solution with subsequent ammonia gas generation. Ammonia is then transported in a nitrogen stream to the GD cell of the FI system where it is absorbed into its acceptor solution containing a mixture of the acid-base indicators cresol red and thymol blue. The maximum increase in the absorbance of the acceptor solution at 580 nm is related to the ammonium concentration in the solid sample. The proposed method is characterized by a linear concentration range of 0.1-5.0 mg NH4+ kg(-1), a limit of detection of 8 mu g NH4+ kg(-1) and a sample throughput of 10 h(-1). A successful application of this method for the determination of ammonium in building materials such as concrete, cement and sand is reported. (C) 2015 Elsevier B.V. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_talanta_2015_04_051.pdf 666KB PDF download