期刊论文详细信息
TALANTA 卷:88
Comparison of three different sample preparation procedures for the determination of traffic-related elements in airborne particulate matter collected on glass fiber filters
Article
Castilho, Ivan N. B.1  Welz, Bernhard1,2  Vale, Maria Goreti R.2,3  de Andrade, Jailson B.2  Srnichowski, Patricia4  Shaltout, Abdallah A.1,5  Colares, Ligia1  Carasek, Eduardo1 
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Fed Bahia, INCT Energia & Ambiente, Inst Nacl Ciencia & Tecnol, CNPq, BR-40170115 Salvador, BA, Brazil
[3] Univ Fed Rio Grande do Sul, Inst Quim, BR-91501970 Porto Alegre, RS, Brazil
[4] Comis Nacl Energia Atom, San Martin, Pcia De Buenos, Argentina
[5] Natl Res Ctr, Dept Spect, Div Phys, Cairo 12622, Egypt
关键词: High-resolution continuum source AAS;    Traffic-related elements;    Glass fiber filters;    Direct solid sampling;    Partial dissolution;   
DOI  :  10.1016/j.talanta.2011.11.066
来源: Elsevier
PDF
【 摘 要 】

Three different procedures for sample preparation have been compared for the determination of Cu, Mo and Sb in airborne particulate matter (APM) collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS). Direct solid sample analysis of the ground filters was compared with microwave-assisted acid leaching with aqua regia and ultrasound-assisted extraction also using aqua regia. The main absorption line at 324.754 nm or the secondary line at 216.509 nm was used for the determination of Cu, depending on the analyte content in the samples. The primary absorption line at 313.259 nm was used for Mo and the secondary line at 212.739 nm for Sb determination. The limits of detection (LOD, 3 sigma) found for the direct solid sampling method, based on ten atomizations of an unused filter were 15 mu g g(-1) for all three analytes, corresponding to 40 ng m(-3) for a typical air volume of 1440 m(3) collected over a period of 24 h. The LOD for the other two methods were less than a factor of two inferior, but the total time required for an analysis was significantly longer. The repeatability of the measurements was between 3 and 9% (n = 5), and the results obtained with the three methods did not show any significant difference. The ratio between the three analytes on the filters from areas of intense traffic was found to be around Cu:Mo:Sb approximate to 4:1:1.4, which suggests that the source of all three elements is brake linings, i.e., related to automobile traffic. When the ratio deviated significantly from the above values, the source of contamination was assumed to be of different origin. (C) 2011 Elsevier B.V. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_talanta_2011_11_066.pdf 626KB PDF download
  文献评价指标  
  下载次数:9次 浏览次数:2次