期刊论文详细信息
SENSORS AND ACTUATORS B-CHEMICAL 卷:247
Highly sensitive detection of Cr(VI) by reduced graphene oxide chemiresistor and 1,4-dithiothreitol functionalized Au nanoparticles
Article
Tan, Feng1  Cong, Longchao1  Jiang, Xiao1  Wang, Yi1  Quan, Xie1  Chen, Jingwen1  Mulchandani, Ashok2 
[1] Dalian Univ Technol, Sch Environm Sci & Technol, Key Lab Ind Ecol & Environm Engn MOE, Dalian 116024, Peoples R China
[2] Univ Calif Riverside, Dept Chem & Environm Engn, Riverside, CA 92521 USA
关键词: Cr(VI);    Au nanoparticles;    Reduced graphene oxide;    Chemiresistor;    Electrical detection;   
DOI  :  10.1016/j.snb.2017.02.163
来源: Elsevier
PDF
【 摘 要 】

Detection of highly toxic Cr(VI) is greatly desired. In the present study, a highly sensitive method for Cr(VI) detection by reduced graphene oxide (rGO) chemiresistor and 1,4-dithiothreitol (DTT) functionalized Au nanoparticles (AuNPs) is reported. The detection strategy is based on the selective binding between DTT functionalized AuNPs1 located in rGO conductive channels and DTT functionalized AuNPs2 in solution through the formation of disulfides induced by Cr(VI) at acidic condition, which results in aggregation of DTT functionalized AuNPs2 on the rGO channels producing a readily measurable resistance change. The response of the chemiresistor is rapid and allows real-time monitoring of Cr(VI). Using this method, as low as 0.9 nM of Cr(VI) in water was detected with good selectivity. The proposed method has great potentials for monitoring of trace Cr(VI) in drinking water. (C) 2017 Elsevier B.V. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_snb_2017_02_163.pdf 730KB PDF download
  文献评价指标  
  下载次数:1次 浏览次数:0次