期刊论文详细信息
SENSORS AND ACTUATORS B-CHEMICAL 卷:235
Chemoresistive micromachined gas sensors based on functionalized metal oxide nanowires: Performance and reliability
Article
Vallejos, S.1  Gracia, I.2  Chmela, O.1  Figueras, E.2  Hubalek, J.1  Cane, C.2 
[1] Brno Univ Technol, Fac Elect Engn & Commun, SIX Res Ctr, Brno 60190, Czech Republic
[2] CSIC, CNM, IMB, Barcelona 08193, Spain
关键词: Micromachined gas sensor;    Nanowires;    Electrodes;    Optimization;   
DOI  :  10.1016/j.snb.2016.05.102
来源: Elsevier
PDF
【 摘 要 】

Chemoresistive micromachined gas sensors with bottom-electrode configuration and based on Pt functionalized tungsten oxide nanowires are fabricated. The performance and reliability of three types of devices with different electrode gap (5, 10 and 15 mu m) are analyzed in dry and humid ambient and towards various analytes (H-2, NO2, EtOH, and CO). Results demonstrate an improved response, sensitivity, and stability with better dynamic of the response for the sensors with the electrode gap of 5 mu m, showing up to 7-fold higher responses and 32-fold faster responses towards hydrogen compared to the sensors with the electrode gap of 10 or 15 mu m. These results are connected with the increment of the density of nanowire junctions across the electrodes with 5 mu m gap; separation that corresponds to half of the length of the wires used in this work. (C) 2016 Elsevier B.V. All rights reserved.

【 授权许可】

Free   

【 预 览 】
附件列表
Files Size Format View
10_1016_j_snb_2016_05_102.pdf 4369KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:0次