| SENSORS AND ACTUATORS B-CHEMICAL | 卷:207 |
| Azide and sulfonylazide functionalized fluorophores for the selective and sensitive detection of hydrogen sulfide | |
| Article | |
| Elsayed, Sameh1,2,3,4  de la Torre, Cristina1,2,3,4  Santos-Figueroa, Luis E.1,2,3,4  Marin-Hernandez, Cristina1,2,3,4  Martinez-Manez, Ramon1,2,3,4  Sancenon, Felix1,2,3,4  Costero, Ana M.1,2,5  Gil, Salvador1,2,5  Parra, Margarita1,2,5  | |
| [1] Univ Politecn Valencia, Ctr Mixto, Ctr Reconocimiento Mol & Desarrollo Tecnol IDM, Valencia 46022, Spain | |
| [2] Univ Valencia, E-46003 Valencia, Spain | |
| [3] Univ Politecn Valencia, Dept Quim, Valencia 46022, Spain | |
| [4] CIBER Bioingn Biomat & Nanotecnol CIBER BNN, Barcelona, Spain | |
| [5] Univ Valencia, Fac Ciencias Quim, Dept Quim Organ, E-46100 Valencia, Spain | |
| 关键词: Hydrogen sulfide; Fluorescence; Azide; Sulfonylazide; In vivo detection; | |
| DOI : 10.1016/j.snb.2014.04.047 | |
| 来源: Elsevier | |
PDF
|
|
【 摘 要 】
Three fluorescent probes (1-3) for the selective and sensitive detection of hydrogen sulfide have been synthesized and characterized. Probe 1 is a coumarin derivative functionalized with an azide moiety whereas 2 contain the azide reactive group into a naphthalene fluorophore backbone. Probe 3 is composed also by a naphthalene fluorophore but, in this case, functionalized with a sulfonylazide reactive moiety. Probes 1 and 3 are non-fluorescent whereas 2 is weakly emissive in HEPES (10 mM, pH 7.4)-DMS0 99:1 (v/v). The emission behavior of the three probes was tested against selected anions, bio-thiols and oxidant molecules. Of all the chemical species tested, only HS- is able to induce an enhancement in the emission intensity (50, 11 and 20-fold for 1,2 and 3, respectively). The observed emission in the presence of hydrogen sulfide is ascribed, in the case of probes 1 and 2, to an azide-amine reduction induced by HS- anion, whereas for probe 3 the sensing mechanism is related with a sulfonylazide-sulfonamide conversion. The three probes are very sensitive to HS- anion with limits of detection of 0.17, 0.20 and 0.40 mM for 1,2 and 3 respectively. Cell viability studies demonstrated that 1-3 probes are essentially non-toxic at concentrations 10-50 mu M and are well suited for in vivo studies. Finally, probe 1 was used for the detection on intracellular HS- anion in HeLa cells by means of confocal microscopy. (C) 2014 Elsevier B.V. All rights reserved.
【 授权许可】
Free
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 10_1016_j_snb_2014_04_047.pdf | 562KB |
PDF