期刊论文详细信息
| OPTICS COMMUNICATIONS | 卷:284 |
| Rayleigh scattering in fused silica samples for gravitational wave detectors | |
| Article | |
| Chen, Xu1  Ju, Li1  Flaminio, Raffaele2  Lueck, Harald3  Zhao, Chunnong1  Blair, David G.1  | |
| [1] Univ Western Australia, Sch Phys, Crawley, WA 6009, Australia | |
| [2] IN2P3 CNRS, Lab Mat Avances, F-69622 Villeurbanne, France | |
| [3] Leibniz Univ Hannover, Max Planck Inst Gravitat Phys, D-30167 Hannover, Germany | |
| 关键词: Rayleigh scattering; Fused silica; Polarisation; Homogeneity; Gravitational wave detectors; | |
| DOI : 10.1016/j.optcom.2011.06.014 | |
| 来源: Elsevier | |
PDF
|
|
【 摘 要 】
Laser interferometer gravitational wave detectors require very high optical quality test masses. We report the bulk Rayleigh scattering in high quality fused silica samples. Results show that the scattering of the high quality fused silica is similar for various grades of fused silica from Heraeus. The total integrated scattering is about 0.7 ppm cm(-1) at 1064 nm wavelength, which agrees with the theoretical value calculated using known fused silica parameters. All samples show Rayleigh scattering ratio inhomogeneity of similar to 4%. (C) 2011 Elsevier B.V. All rights reserved.
【 授权许可】
Free
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 10_1016_j_optcom_2011_06_014.pdf | 1375KB |
PDF